Product Details:
Payment & Shipping Terms:
|
Type: | Suspension Type Toughened Glass Insulator | Mechanical Damage Load: | >100KN |
---|---|---|---|
Battering Load: | >678KN | Electromechanical Load Test Value: | 75KN |
Weight: | 4.1kg | Nominal Height: | 146mm |
Nominal Diameter: | 255mm | Minimum Nominal Creepage Distance: | 320mm |
High Light: | powerline tools,transmission tools and equipment |
Transmission Line Tools High Voltage Disc Anti-fouling Suspension Type Toughened Glass Insulator
Characteristic
Insulators are made of toughened glass. Because of the high mechanical strength of the glass insulator surface, it is not easy to crack on the surface.
Insulator is a special insulation control, which can play an important role in overhead transmission lines.
Initially, insulators were mostly used in poles, and gradually developed into high-voltage wire towers with many disc-shaped insulators hanging at one end.
Using glass insulator, it can cancel the operation process of insulator of charged periodic preventive test. This is due to every damage to tempered glass causes damage to the insulator, which operators can easily find when patrolling the wire. Toughened glass insulators are widely used because of the characteristics of zero self-breaking and easy maintenance. Insulator is one of the key components of high voltage transmission line, and its performance directly affects the operation safety of the whole transmission line.
Product parameters
Model | BYLXY-70 | BYLXY1-70 | BYLXY-100 | BYLXY-120 | BYLXY3-160 | BYLXY3-210 | BYLXY-240 | BYLXY-300 | |
Mechanical damage load≥ KN |
70 | 70 | 100 | 120 | 160 | 210 | 240 | 300 | |
Battering load≥ KN |
565 | 565 | 678 | 678 | 1017 | 1017 | 1017 | 1017 | |
Electromechanical load test value/h KN |
52.5 | 52.5 | 75 | 90 | 120 | 157.5 | 180 | 225 | |
Nominal Height H mm |
127 | 146 | 146 | 146 | 155 | 170 | 170 | 195 | |
Nominal diameter of insulator D mm |
255 | 255 | 255 | 255 | 280 | 280 | 280 | 320 | |
Minimum nominal creepage distance mm |
320 | 320 | 320 | 320 | 380 | 390 | 390 | 485 | |
Peak voltage tolerance for lightning full - wave shock kv |
≥100 | ≥100 | ≥100 | ≥100 | ≥105 | ≥105 | ≥105 | ≥105 | |
Effective value of power frequency voltage≥ kv |
1min wet resistance | 40 | 40 | 40 | 40 | 42 | 42 | 42 | 45 |
Breakdown | 130 | 130 | 130 | 130 | 130 | 130 | 130 | 130 | |
Weight/set (kg) | 3.77 | 3.78 | 4.1 | 4.2 | 6.2 | 6.7 | 6.8 | 10.7 |
Advantage
Good aging resistance, good structural stability, good pollution flashover resistance, high line operation efficiency, light weight, excellent mechanical performance, excellent electrical corrosion resistance and so on.
Contact Person: Mr. Green Lu
Tel: +86 18036062799